High Frequency Single Phase Futuristic UPS System For SMEs & Corporate 1 KVA to 3 KVA

We offer genuine Online uninterruptable power supply systems with clean and reliable power source for a wide range of critical applications. In an age where future planning, development and growth is greatly dependent on information technology, the source of clean and dependable power becomes an element of high important.
The commercial main supply is subjected to a plethora of power disturbances like high voltage, low voltage, continuous voltage fluctuations, brownout, blackout, surge, electrical load and it applications. Therefore a lot more study and analysis needs to be done in selecting a good UPS that can ensure total protection to the load and increase system reliability and uptime. POWERTEX is dedicated in designing and producing quality power supply system since 2002. True On-Line Double Conversion type UPS, Pure Sine wave output Overload and output short circuit protection. Suitable for all types and capacities of batteries, Smooth and silent operation. Compatible with the intelligent data protection package.


Dealers for APC UPS Systems ENERTECH UPS Systems and UNILINE Energy Systems.


Also available for high frequency UPS Systems 1 KVA-3KVA

Technical Specifications

Technology PWM Technology, Using IGBT Device, With High Switching Frequency
Switching Frequency High Frequency Design ensures
Wide Input Range 160-260 (Single Phase) 315-415(3 Phase) 45-55 Hz
Output Voltage 230 VAC (Single Phase) 50 HZ = /-1%
Ratings Single Phase 1.0 KVA to 7.0 KVA 3 Phase 10 KVA – 40 KVA
Output Power Factor 0.8 lagging to unity
Transient Response For 100% step load change output stays within +/- 5% and recovers within 5 msecs i.e. 1/4th cycle.
Metering Multi Display Meter to display following parameters Output Voltage Output Current Battery Voltage Frequency Meater Status related to UPS working like load on UPS,
Wave Form Pure Sine Wave
Distortion Total Harmonic Distortion less than 2% for linear load and less than 5% for non-linear load.
Overload Rating 100% Continuous 150% for 30 seconds.
DC Volts 1.0 KVA to 7.0 48V/72/96/120V 10.0 – 40K 240V/360/
Operating Temperature Relative Humidity 0 to 50° C, 95% R.H. (Maximum)
Inverter Efficiency; Better than 90%
Protections Output Over-Voltage Output Overload Output Short Circuit Battery Under-Voltage Forced Air-cooling to protect electronic & other components from overheating
Indications Mains/Charger ON Inverter ON System Overload Battery Under-Voltage Output Under/Over Voltage
Alarms Mains Fail (Musical Alarm) Battery Low Warning (Musical Alarm)
Low Noise Less than or Equal to 45 dB (A) (Standard) at 1.0 mtr.
Bypass Arrangement Manual bypass optional solid state static bypass provided;
Interface Port RS 232 standard interface port provided to shut down the file server (Optional)
SNMP Software SNMP software for network & manage client server structures (Optional)
Battery Charger Charger is designed on Boost / Trickle (CCCV) principle to keep batteries in top condition .Pulsating-current design ensures long battery life.

Applications

  • 1 KV is used for Small Office Network Applications.
  • 10KV is used for IT and Software Comapanies
  • Network Devices: Hubs, Routers, Bridges
  • Remote Telecommunications Units
  • Office Telecommunications Systems
  • Voice Mail and E-Mail Servers
  • Bio Medical Test and Diagnostic Equipments
  • Engineering Network Servers
  • Process Automation & Control Equipment
  • Mission Critical LAN &WAN Servers etc.